| INTRODUCTION  
                                 MF-840 is 
                                  solvent free, two components and room temperature 
                                  cured polysulfide sealant. It has excellent 
                                  adhesion to most building materials such as 
                                  glass, aluminum alloy, galvanized-steel and 
                                  so on. The product is formulated to facilitate 
                                  optimal performance on both mechanical and manual 
                                  application equipment. MF-840 is used for the 
                                  manufacture of IG units (IGU) or double glazing 
                                  as a secondary seal in conjugation with butyl 
                                  as the primary sealant. MF-840 can also be used 
                                  singly as primary seal without butyl. 
                                 
                                  CHARACTERISTIC 
                                MF-840 is a two parts component sealant cure 
                                  at room temperature. It is good at adhesion 
                                  and has excellent resistance to air aging. 
                                It is free of solvent with low boiling point 
                                  and it has no pollution to the environment. 
                                 
                                  APPLICATION 
                                MF-840 is mainly applied in the sealing of 
                                  IG insulated glass for building, construction, 
                                  transportation and refrigeration/freezing/chilling 
                                  industries. 
                                 
                                  NOTE 
                                Polysulfide sealant is not recommended to be 
                                  used together with silicone sealant, or adhesion 
                                  would be affected. The operating temperature 
                                  should be at least 5℃ or above, or curing time 
                                  and adhesion would be affected. 
                                 
                                  APPLICATION METHODS 
                                Surface cleaning 
                                  Surfaces where polysulphide shall be applied 
                                  must be cleaned, dried and free of grease. 
                                 
                                  Mixing 
                                  Part A and Part B must be mixed according to 
                                  the designated ratio, A:B = 100:6-14. Curing 
                                  speed can be adjusted (the larger the Part B, 
                                  the faster the curing time and, vice versa). 
                                  Part A and Part B should be mixed thoroughly 
                                  until there is no chromatic aberration. 
                                 
                                  Sealant applied direction 
                                  The sealant is always applied along one direction 
                                  to prevent any bubbles from creating. 
                                
  |